Avoiding Cracks in Stack Bond Barrow-in-Furness

Unreinforced stack bond walls are more likely to crack vertically than walls built with running bond. That is why ACI 530 requires any masonry laid in other than running bond to have horizontal joint reinforcement spaced no further than 4 feet apart in order to control cracking.

Hodgson K
01229 827501
23a Kirkstone Crescent
Barrow in Furness
 
A.m.c Builders
01229 823337
13 Cheltenham Street
Barrow in Furness
 
Britannia Construction Cumbria
01229 811601
Unit 54 Furness Business Park
Barrow in Furness
 
Bryn Clark Building And Roofing
01229 825555
Daveys Yard
Barrow in Furness
 
Gmc Builders And Roofers
01229 430846
54 Victoria Avenue
Barrow in Furness
 
George Miles
01229 828301
90 Crellin St
Barrow in Furness
 
T.p Mcnulty Construction Ltd
01229 832386
19 The Crescent
Barrow in Furness
 
Builders Supply
01229 829333
Park Road
Barrow in Furness
 
Schofield Construction
01229 830004
Units 41 42 Trinity Enterprise
Barrow in Furness
 
Builders A M C
01229 823086
13 Cheltenham St
Barrow in Furness
 

Avoiding Cracks in Stack Bond

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: August 1, 1994

I have heard that masonry laid in stack bond is more likely to crack than masonry laid in running bond. Why? Assuming walls were built using the same mortar and brick, why wouldn't the vertical joints in stack bond be as strong as the horizontal joints in both stack bond and running bond? Unreinforced stack bond walls are more likely to crack vertically than walls built with running bond. That is why ACI 530 requires any masonry laid in other than running bond to have horizontal joint reinforcement spaced no further than 4 feet apart in order to control cracking. In a running bond wall, any vertical crack must either pass through a brick at every other course or follow the mortar through head and bed joints. Usually the weakest path is through the units. Therefore the wall's strength is determined mainly by the strength of the units, not the mortar bond strength at head joints. In stack bond walls that are not reinforced, resistance to vertical cracking depends solely on mortar-to-brick bond, which is weaker in vertical joints than in horizontal joints. Better bond is developed in horizontal joints because the weight of the masonry keeps the joints under pressure throughout construction. If cracks do develop, they generally are very small because of this compression.

Click here to read full article from Masonry Construction